Water & Soil Analysis Kits

Home Water & Soil Analysis Kits

Water & Soil Analysis Kits

Model No: PSAW-59, PSAW-60 ,PSAW-61, PSAW-62, PSAW-64

WATER & SOIL

ANALYSIS KITS

Product Information

PARAMETERS:-

 

59

60

61

62

64

pH

Ö

Ö

Ö

Ö

Ö

Cond.

Ö

Ö

Ö

Ö

Ö

TDS

Ö

Ö

Ö

Ö

Ö

DO

Ö

Ö

Ö

Ö

Ö

mV (ORP)

Ö

Ö

Ö

Ö

Ö

Salinity

Ö

Ö

Ö

Ö

Ö

Turbidity

       

Ö

Colorimeter

       

Ö

Temp.

Ö

Ö

Ö

Ö

Ö

SPECIFICATIONS:

Model

 

PSAW-59

PSAW-60

PSAW-61

PSAW-62

PSAW-64

Product

 

µP Water & soil Analysis Kit

Water & soil Analysis Kit

Water & soil Analysis Kit

Water & soil Analysis Kit

Water & soil Analysis Kit

Display

 

16 x 2 Character LCD Display

3 ½ Digit LCD

3 ½ Digit LCD

3 ½ Digit LCD

pH

   

Range

 

0 to 14pH

0 to 14pH

0 to 14pH

0 to 14pH

0 to 14pH

Resolution

 

0 .01 pH

0 .01 pH

0 .01 pH

0 .01 pH

0 .01 pH

Accuracy

 

0.01 ±1 Digit

0.01 ±1 Digit

0.01 ±1 Digit

0.01 ±1 Digit

0.01 ±1 Digit

Temp. Comp.

 

0 to 100°C (Auto Manual)

0 to 100°C (Auto Manual)

0 to 100°C (Auto Manual)

0 to 100°C (Auto Manual)

0 to 100°C (Auto Manual)

CONDUCTIVITY (EC)

   

Range

 

0-20, 0-200µS,

0-2, 0-20, 0-200mS

0-20, 0-200µS,

0-2, 0-20, 0-200mS

0-20mS

0-20mS

0-20mS

Resolution

 

0.01µS/cm

0.01µS

0.01µS

0.01mS (10µS).

0.01mS (10µS).

Range Selection

 

Automatic

Manual

___

___

___

Accuracy

 

±0.5% FS±1 Digit

±0.5% FS±1 Digit

±0.5% FS±1 Digit

±0.5% FS±1 Digit

±0.5% FS±1 Digit

Cell Constant

 

Adjustable (0.05 to 10.5)

Adjustable (0.04 to 1.5)

Pre-Adjusted

Pre-Adjusted

Pre-Adjusted

Temp. Coefficient

 

Adjustable (0.4 to 4.0)

2%

2%

2%

2%

Temp. Comp.

 

5-50°C (Auto / Manual)

Adjustable for Table

Adjustable for Table

Adjustable for Table

Adjustable for Table

Reference temp.

 

Suitable (5-50°C)

Adjustable for Table 25°C

Adjustable for Table 25°C

Adjustable for Table 25°C

Adjustable for Table 25°C

TEMPERATURE

   

Range

 

0-100°C

0-100°C

0-100°C

0-100°C

0-100°C

Resolution

 

0.1°C

0.1°C

0.1°C

0.1°C

0.1°C

Accuracy

 

±0.1°C±1 Digit

±0.1°C±1 Digit

±0.1°C±1 Digit

±0.1°C±1 Digit

±0.1°C±1 Digit

Sensor

 

Semi Conductor type

Semi Conductor type

Semi Conductor type

Semi Conductor type

Semi Conductor type

TDS

           

Range

 

0-20, 0-200 ppm, 0-2, 0-20, 0-200 ppt.

0-20, 0-200 ppm, 0-2, 0-20, 0-200 ppt.

0-20ppt.

0-20ppt.

0-20ppt.

Range Selection

 

Automatic

Manual

_____

_____

_____

Resolution

 

0.01ppm

0.1ppm

0.01ppt

0.01ppt

0.01ppt

Accuracy

 

±0.5% FS±1 Digit

±0.5% FS±1 Digit

±0.5% FS±1 Digit

±0.5% FS±1 Digit

±0.5% FS±1 Digit

Cell Constant

 

Adjustable (0.5 to 10.5)

0.4 to 1.5 on Display

Pre-Adjusted

Pre-Adjusted

Pre-Adjusted

DO

   

Range

 

0-20 ppm

0-20 ppm

0-20 ppm

 

0-20 ppm

Resolution

 

0.1ppm

0.1ppm

0.1ppm

 

0.1ppm

Accuracy

 

0.1ppm±1 Digit

0.1ppm±1 Digit

0.5ppm±1 Digit

 

0.1ppm±1 Digit

Temp. Comp

 

Auto / Manual ( 5°C to 55°C)

Manual ( 5°C to 55°C)

Manual ( 5°C to 55°C)

 

Manual ( 5°C to 55°C)

DO Sensor

 

Gold/Silver Probe

Gold/Silver Amperometric Probe

Gold/Silver Amperometric Probe

   

mV (ORP)

   

Range

 

0 to 1999.9mV

0 to 1999.9mV

____

____

0 to 1999.9mV

Resolution

 

0.1mV

0.1mV

____

____

1mV

Accuracy

 

±1mV ±1 Digit

±1mV ±1 Digit

____

____

±1mV ±1 Digit

Turbidity

   

Range

 

____

0-1000 JTU

____

____

0-1000 JTU

Resolution

 

____

1 JTU

____

____

1 JTU

Accuracy

 

____

± 3 FS ± 1 Digit

____

____

± 3 FS ± 1 Digit

Sample System

 

____

30mm Clear Glass Tube

____

____

30mm Clear Glass Tube

Salinity

           

Range

 

0-20, 0-200 ppm, 0-2, 0-20, 05ppt

0-50ppt

0-50ppt

0-50ppt

 

Resolution

 

0.01ppm

0.1ppt

0.1ppt

0.1ppt

0.1ppt

Accuracy

 

±1% of Range ± 1 Digit

± 0.5%FS ±1 Digit

±0.5% FS ±1 Digit

±0.5% FS ±1 Digit

±0.5% FS ±1 Digit

COLORIMETER

           

POWER SUPPLY

 

6V Rechargeable Battery

1.5Vx 6Dry Cells

1.5Vx 6Dry Cells

1.5Vx 6Dry Cells

1.5Vx 6Dry Cells

   

Or 230V ±10%AC, 50 Hz.

Or 230V ±10%AC, 50 Hz.

Or 230V ±10%AC, 50 Hz.

Or 230V ±10%AC, 50 Hz.

Or 230V ±10%AC, 50 Hz.

STORAGE

 

1000Sample

       

STANDARD ACCESSORIES

 

pH Electrode, Cond/ TDS/ Salinity Cell, temp, Probe, Do Probe, Dry Cell Container Main Lead, Operation Manual, Bottles for pH Solution & pH